- Rating
- 4
- Clarity
- 3
- Confidence
- 4
- Originality
- 2
- Quality
- 3
- Significance
- 3
Read review
Summary
The paper addresses negative guidance of diffusion models by sampling given either a reference set for or score of . To do so, they propose a SMC sampler along intermediate distributions , where a classifier is trained at every SMC step using samples of and weighted samples of targetting the unconditional marginal.
Strengths and weaknesses
Strengths
Negative guidance is an important problem and the application of SMC can make it more trustworthy. The theoretical foundation is strong in the infinite particle case.
Weaknesses
While SMC is exact in infinite particle limit, the choice of intermediate distributions often highly affects the performance in the finite particle case. The requirement of M=1024 particles for a 3d toy experiment is highly prohibitive, as it might be an indicator of a poor SMC path. The lack of ablation on lower particle count is concerning.
I am also worried about the reweighting to compute the classifier risk. In particular the importance weight intuitively feels like a poor choice, as the path diverges from condition , so the weights will likely have high variance and collapse when using a finite set of samples.
Finally, there is extremely limited experimental evaluation with only a CIFAR-10 diffusion model and a low-dim GMM, and no visual image results despite being a diffusion model paper.
Questions
How does the performance of the GMM or CIFAR-10 compare with fewer than 1024 or 128 particles?
How often does your method perform resampling? A graph showing ESS at every SMC iteration would be helpful.
What is the ESS of the or you get by reweighting from ? If it is low, how much does it affect the classifier variance (and thus, the weight variance)?
Limitations
yes
Paper formatting concerns
N/A
Final justification
The experiments presented in the rebuttal resolve the concerns I have with the lack of empirical results and finite-particle performance of SMC under this annealing path: 128 particles is enough to outperform previous methods and nearly match the oracle performance in the higher-dimensional Stable Diffusion case, and few resampling steps (1-7) are needed which avoids ancestry collapse.
Meta-review
The paper introduces a new form of negative guidance for generative diffusion models based on sequential Monte Carlo (SMC) resampling. The method is related to Dynamic Negative Guidance (DNG) in that it interprets negative guidance as a form of online Bayesian inference. Unlike DNG, however, it relies on information from a full batch rather than exclusively on local information.
The reviewers agree that the paper is clearly written, that the problem area is important, and that the methodology appears broadly sound, although some aspects require further clarification. Reviewer Noo2 points out that several statements concerning the comparison with DNG are imprecise and potentially misleading. The reviewers also agree that the experimental section is weak for a paper aimed at addressing a concrete practical problem.
Personally, I am not yet convinced that the proposed method constitutes a significant improvement over DNG. The original DNG paper already shows that the method is exact when the score estimates are exact, while the proposed approach does not address the problem of inaccurate score estimation. The authors also claim that DNG does not offer a mechanism for trading computational cost against sample quality. However, this characterization is not entirely accurate, since such a trade-off can be obtained by increasing the number of function evaluations, causing the Bayesian approximation to converge toward the true posterior.
I agree that the error profile of DNG is currently less precisely understood than that of SMC, but I believe the corresponding claims should be softened and presented with greater nuance.
Overall, I think the paper is promising, but its empirical validation needs to be substantially strengthened. In addition, the positioning of the method and its comparison with existing approaches should be made more transparent, precise, and balanced.