- Rating
- 4
- Clarity
- 3
- Confidence
- 4
- Originality
- 3
- Quality
- 3
- Significance
- 3
Read review
Summary
This paper addresses post-training quantization (PTQ) for large language models (LLMs) under extreme low-bit settings (W4A4 and W4A4KV4). The authors argue that existing rotation-based methods have reached a saturation point due to heuristic approximations and a lack of rigorous error modeling. They propose DICEQuant, a two-stage framework: (1) CURE (Coupled Underflow-Rounding Error surrogate) , a differentiable loss that explicitly models rounding and underflow errors to learn activation rotation matrices on the Stiefel manifold without straight-through estimators; (2) DCR (Distortion-Compensated Rounding) , a weight optimization method that derives a shifted optimal center to compensate for input distortion and uses Hessian-weighted shaping to align with global task loss. Experiments on LLaMA-2/3 and Qwen3 families show consistent improvements over strong baselines (SpinQuant, OSTQuant, DartQuant) in both perplexity and zero-shot accuracy, with notable gains in the aggressive W4A4KV4 regime.
Strengths and weaknesses
Strengths
- This paper identifies a genuine blind spot in existing PTQ: the twofold blindness (ignoring upstream distortion and downstream task sensitivity) and provides formal derivations (Proposition 3.1, Theorem 3.2) to justify the proposed solutions. The CURE error bound explicitly coupling range and dead-zone occupancy is novel.
- Replacing STE-based heuristics with a differentiable, exact gradient formulation (CURE) and introducing a shifted optimal center for weight rounding are well-motivated and technically solid. The bilateral feedback update rule is derived systematically.
- Evaluation covers multiple model families (7B–70B), two quantization regimes (KV16 and KV4), and up to nine zero-shot tasks. Ablation studies confirm the contribution of each component.
- The paper reports prefill speedup (2–3.4×), memory savings (~3.7×), and compares calibration overhead (GPU hours) against baselines, demonstrating practical benefits.
Weaknesses
- No error bars or confidence intervals are reported. Given that calibration data sampling introduces randomness, it is unclear whether the reported improvements (e.g., 65.78 vs. 65.37 in Tab.1) are statistically robust. This is expected for a top-tier conference.
- A recent method GPTAQ (2025.04) is only shown in an ablation (Tab.3) but absent from main tables, even though it directly relates to input-aware weight optimization. This undermines the claim of “state-of-the-art” completeness.
- On Qwen3-14B (W4A4KV16), DICEQuant achieves 71.38 vs. 71.13 (OSTQuant) and 70.87 (DartQuant) – a difference of 0.25–0.5 points, which may be within run-to-run variance. The paper’s phrasing (“significantly surpasses”) is somewhat overclaimed.
- CURE involves two temperature parameters (α, τ). While Tab.4 shows their effect, there is no guidance on how to select them across different models or bit-widths, harming reproducibility.
- No discussion of where DICEQuant underperforms (e.g., smaller models, certain tasks, or when calibration size is reduced). This would help readers understand practical limitations.
Questions
- How sensitive is DICEQuant to calibration set size? Could you provide a curve showing perplexity/accuracy vs. number of calibration samples (e.g., 32, 64, 128, 256) on a representative model? This is critical for users with limited calibration data.
- Why was GPTAQ excluded from the main comparison tables? GPTAQ also addresses input distortion via asymmetric calibration. Including it would clarify whether DCR offers distinct advantages beyond that baseline.
- Can the CURE objective be extended to per-token or per-channel quantization? Currently it assumes per-group mid-tread. Would the bound in Proposition 3.1 change under asymmetric quantization?
- The Bilateral Feedback update (Eq.14) uses a Neumann series truncation. Have you measured the impact of including higher-order terms (e.g., up to L^2 or L^3)? Is the convergence rate stable across layers and models?
- Could you report the end-to-end inference latency (not just per-block prefill/decoding speed) for a full model (e.g., LLaMA-7B) on a specific hardware (e.g., A100) with actual batch inference? The current Table 2 and 9 are informative but somewhat partial.
Limitations
- The CURE bound (Proposition 3.1) relies on the high-resolution assumption (uniform rounding error). In 4-bit quantization, this assumption may be violated, and the bound could become loose. The paper does not verify its tightness empirically.
- Although the paper provides GPU-hour comparisons, the per-layer Hessian computation (H_out = E[gg^T]) requires a backward pass per calibration batch, which doubles the forward+backward cost. For 70B models with many layers, this may be nontrivial even if reported as “1.0h”. A breakdown of time spent on CURE vs. moment accumulation vs. DCR would be helpful.
- Because DCR uses \hat{x} from previously quantized layers, quantization errors can accumulate. The paper does not propose any global refinement (e.g., end-to-end tuning) to mitigate this, unlike methods like OmniQuant or AffineQuant that allow block-wise reconstruction.
Paper formatting concerns
None
Dear Reviewer iXwr,
We greatly appreciate the reviewer's recognition of the significance and originality of our work, as well as the careful attention given to its theoretical formulation, experimental evidence, and practical scope. We attach great importance to your valuable suggestions, and below are our point-by-point responses.
We have run the requested seed analysis on LLaMA-3 8B W4A4KV4 with 5 independent calibration draws, keeping all other settings identical. The results confirm that the reported 9-task average accuracy is robust.
GPTAQ is not one of the standard methods used by the papers we compare against, so inserting its weight solver into the main tables would create a non-standard hybrid, not a faithful comparison. Our baselines (QuaRot, SpinQuant, OSTQuant, DartQuant) are rotation-based W4A4 pipelines, each with native GPTQ weight-rounding implementation, and GPTAQ is not part of that suite.
The distinction is theoretical. Standard weight PTQ is twofold blind: it assumes a clean input x^=x (ignoring upstream distortion) and weights all output channels uniformly (blind to task sensitivity). GPTAQ's asymmetric calibration removes only the first, as its OBC solve uses the input second moment Σx^x^ with no output-side Hessian. DCR keeps the same input-aware center $W^{*} $ (Thm 3.2) but its objective (Eq. 12) also couples in the output task-sensitivity Hout=E[gg⊤], removing the second. In Fig. 1, GPTAQ's Euclidean step can land on a steep high-loss slope, whereas the Hout metric reaches the flat task-loss valley.
The ablation proves this directly. In Table 3, varying only the weight stage under a fixed CURE rotation, DCR improves on GPTAQ by +1.67 in accuracy and -0.38 in PPL. Since rotation, calibration data, and grid are identical across those rows, the gain isolates the added output-sensitivity metric Hout as DCR's distinct advantage beyond GPTAQ.
We will replace "significantly surpasses" with "consistently outperforms" as the global claim, since some gaps are modest, for example Qwen3-14B W4A4KV16 at 71.38 versus 71.13 (+0.25). The hard-regime and low-precision margins remain substantial, for instance +1.68 over SpinQuant and +4.40 over QuaRot (61.38) on LLaMA-3 8B W4A4KV4, and these we will continue to describe as substantial.
We use a single default, α=80 and τ=0.05, for every model and both KV regimes in the paper, and Table 4 shows a flat basin around it, so the choice is robust and is not tuned per model. The two temperatures also transfer across bit-widths by construction. α (Eq. 7) only sharpens the smooth approximation of the per-group maximum A(v)=maxi∣vi∣, a scale statistic independent of the quantization grid, so it does not depend on bit-width. τ (Eq. 8) sets the transition width of the underflow sigmoid around the dead-zone boundary t(v)=A~(v)/(2qmax), which already carries the bit-width through qmax, so a fixed τ holds within a bit-width and one only rescales τ∝1/qmax for a substantially different one.
We will add a limitations paragraph, as the margin narrows in three identifiable places rather than being uniform. By model, the only setting where DICEQuant trails is the large LLaMA-2-70B W4A4KV4 (70.71 versus OSTQuant 70.84), while on the smallest model LLaMA-2-7B the lead is real but narrow (63.27 versus 63.18), and the largest gains are on mid-size models in the aggressive regime (+1.68 over SpinQuant on LLaMA-3 8B W4A4KV4). By task, DICEQuant leads the 9-task average but is edged out on a few individual tasks such as ARC-e and PIQA (Table 6). By calibration size, all results use the standard 128 samples, and because the DCR statistics are second-moment aggregates with variance scaling as 1/N, the advantage is expected to narrow at very small sizes.
We ran the requested sweep on LLaMA-3 8B W4A4KV4, varying only the number of WikiText2 calibration sequences of 2048 tokens each. DICEQuant is highly insensitive to calibration set size, its WikiText2 PPL staying within about 0.1 across 32 to 512 samples, so it works well even with very little calibration data.
Yes. Prop 3.1 is proved for the per-group symmetric case for clarity, but both the bound and the objective are agnostic to how a group is defined, so per-token and per-channel are simply different choices of the group. The bound E[MSE(v)]≲(A(v)2/qmax2)(1/12+N0(v)/4d) is written for a generic group vector v, and CURE minimises $ \mathcal{L}_{\mathrm{CURE}}(v_g(R)) $ over the collection of quantization groups G. Redefining a group as a token or a channel changes only which elements enter A(v)=maxi∣vi∣ and the underflow count N0, not the form of the bound or the objective. Under asymmetric quantization the bound keeps its two-term structure: one replaces vi/Δ by (vi−z)/Δ with a per-group zero-point z, which recenters the clamp and the dead-zone around z, so the underflow set becomes the elements within Δ/2 of z. The rounding term 1/12 is unchanged and the underflow term N0/4d remains an exact bound, with the symmetric case recovered at z=0.
The 2nd-order truncation is a deliberate compute-accuracy choice: a higher order roughly doubles the per-iteration cost for only an O(∥L~∥2) correction that the iteration already absorbs. After diagonal normalization L=D1/2(I+L~) (App B.2), L~ is strictly lower-triangular, hence nilpotent and small in norm, so (I+L~)−1=I−L~+L~2−⋯ decays geometrically and Eq. 14 keeps it through the low-bit-critical cross term LoutΔLin⊤ (App A.3, B.3). The next order adds the $\tilde{L}^{2} $ products, roughly doubling the triangular matmuls per iteration, yet Eq. 14 is a fixed-point iteration (Δ(t)=W∗−W^(t), App B.3) that re-injects the residual, so that same $ O(\lVert\tilde{L}\rVert^{2}) $ correction is captured far more cheaply by one extra iteration than by a higher-order step. Convergence is stable because the contraction is bounded by $\lVert\tilde{L}\rVert $ and the Tikhonov damping λ (App B.1).
Table 9 is already a full-model, end-to-end measurement rather than a per-block microbenchmark: it reports the generation throughput (tokens per second) of the complete model on real GPU hardware, so its reciprocal is exactly the end-to-end decoding latency the reviewer asks for.
The assumption only sets the numerical constant of the rounding term, whereas the content of Prop 3.1 (the decomposition into an outlier-range term and an exact dead-zone term, and the coupling between them) does not depend on it. The underflow term N0/4d is an exact pointwise bound (vi2<Δ2/4) with no resolution assumption, and it is precisely the effect that grows at 4-bit and that prior rotation methods, minimising only the range A(v), ignore. Even without the assumption, the strict bound ∣ei∣≤Δ/2 keeps the same two-term structure and moves the rounding constant only within [1/12,1/4], so CURE optimises the same trade-off. And minimising the surrogate demonstrably lowers the true 4-bit error: Fig. 2 shows measured activation MSE falling from 5.88e-1 to 4.16e-2, with Table 4 confirming the trend.
The 1.0h at 70B in Table 10 is the CURE rotation-learning time only, DCR being a separate stage, and DCR calibration runs at roughly 2x a comparable GPTQ pass. This is because the layer-output Fisher Hout=E[gg⊤] is collected offline as a one-time backward over the 128-sample set (App B.4.1). One pass yields g=∂L/∂y at every layer at once, so it does not scale with the depth of a 70B model. Apart from it, DCR does no gradient-descent training, matching a standard GPTQ reconstruction.
DCR already targets the accumulated distortion, because Σxx^ and Σx^x^ are computed on the quantized input x^ that carries the propagated error, and W∗=WΣxx^(Σx^x^+λI)−1 (Thm 3.2) is defined against exactly that distortion. so a separate end-to-end tuning stage is not needed for our results.